Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.
We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.
The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence
Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
general exhaust temperature of boiler furnace
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Boilers, furnaces and engines are important users of fossil fuels. The general relationship between the O 2 supplied and the concentration of CO2 and CO in the exhaust is illustrated in Figure 5. As the air level is increased and approaches of the theoretical air, the con- Exhaust Gas Temperature and Supplied Combustion Air TemperatureGet Price
The maximum temperature that we recommend you set your radiator output to is 80 °C. If you have a conventional boiler system, your water cylinder will have its own thermostat. This is usually fitted on the side of the tank. You should set the temperature between 60 and 65 °C but for maximum efficiency, it should be set to around 60 °C.Get Price
1.4.3 Emissions3-4 The emissions from natural gas-fired boilers and furnaces include nitrogen oxides (NOx), carbon monoxide (CO), and carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), volatile organic compounds (VOCs), trace amounts of sulfur dioxide (SO2), and particulate matter (PM). Nitrogen Oxides -Get Price
3 Things to Know About Your Furnace's Exhaust FlueGet Price
reverberatory furnace corresponds to the aluminium pouring point temperature 650 – 750 °C. In this scenario, at least 40% of the energy input to the furnace is still lost as waste heat. This waste heat can be use for various purposes .Combustion air preheat can increase furnace efficiency byGet Price
(a) Power Boiler - A boiler in which steam or other vapor is generated at a pressure of more than l5 psi. (b) High Pressure, High-Temperature Boiler - A boiler in which water, oil, or other fluid is heated and intended for operation at pressures in excess of l60 psi and/or tem peratures in excess of 250 degrees Fahrenheit.Get Price
Temperature indicator Thermocouple, liquid in Fuel temperature, flue gas glass temperature, combustion air temperature, boiler surface temperature, steam temperature Draft gauge Manometer, differential Amount of draft used pressure or available TDS meter Conductivity Boiler water TDS, feed water TDS, make-up water TDS.Get Price
temperature rises at a rate of 0.56°C (1°F) for each heat input of 2.095 kJ/kg (1 Btu/lb) If we take water at 0°C (32°F) and we add 419 kJ/kg (180 Btu/lb) then we will increase the temperature of the water by 100°C (180°F) This rise in temperature can be detected and is called Sensible Heat (Specific Enthalpy - Water)Get Price
• Low-pressure boilers are designed to withstand a maximum of 15 psig steam or a M.A.W.P. 160 psig water. The boilers can be classified according to the following criteria. According to flow of water and hot gases: 1. Water tube. 2. Fire tube. In water …Get Price
temperature of the boiler water above 212°F and producing steam. This steam rises throughout the building to the room radiators. A steam system does not have a circulating pump and the burner can cycle on and off either to keep the idling boiler at approximately 180°F, or to increase boiler temperature to produce steam needed to heat the rooms.Get Price
Coal-fired boilers are mainly operated at either subcritical or supercritical conditions. From a thermo-physics perspective, two phase mixtures of water and steam are replaced by a single supercritical fluid when the boiler pressure increases above the critical pressure of 22.12 MPa and the corresponding saturation temperature of 374 °C (Shen and Cheng, 2004).Get Price
A low temperature (e.g. below 80-85 C) will cause colder feed water to enter the boiler thus increasing the fuel cost due to the need for more heating for evaporation. An overheated hot well may cause evaporation of water at the suction of feed pump (e.g. cavitation) and cause vapor lock in the feed pump and loss of suction.Get Price
Aug 19, 2019 · The design is fairly similar to a fire-tube boiler, but instead of the furnace heating fire tubes to heat water in a tank, the furnace heats water tubes inside the furnace. In the same way, a fuel source is burned in the furnace, causing the water tubes inside to heat up. Once again, when the water is boiled, steam is generated and moved Get Price
Table 14 Basic Oxygen Furnace Offgas Composition 40 Iron/Steel Production 42 In Aluminum Refining and Melting 43 Process Exhaust Gases in Metal Casting 45 Boiler Exhaust Gases 48 Table 19 Unrecovered Waste Heat and Work Potential from Ethylene Furnaces 49 Exhaust Gases 53 Table 21 Unrecovered Waste Heat in Different Temperature Groups 55Get Price
The feedwater is pre-heated in order to increase the efficiency of the plant. The circulating water to the exhaust gas boiler heats the feed water and the three-way valve on the inlet to the heat-exchanger controls the temperature. The economizer inlet temperature must never fall below 135°C to avoid corrosion on the economizer tubes.Get Price
g. Feedwater inlet temperature specified on the data sheet. h. Purity of produced steam as specified in the project specification in ppm mass (mg/kg) with consideration of ppm mass (mg/kg) of total solids in the boiler water. The boiler manufacturer shall state the maximum TDS in the boiler water at which the required steam purity can be obtained.Get Price
Boilers rely on the water to protect the steel boiler tubes from the temperatures in the furnace which greatly exceed the melting point of the tube material. A buildup of deposits inside the tubes will produce an insulating layer which inhibits the ability of the water to …Get Price
Exhaust Temperature (o F) (o C) Chemical Oxidation: 1350 - 1475: 730 - 800: Annealing furnace: 1100 - 1200: 590 - 650: Fluidized-bed combustion: 1600 - 1800: 870 - 980: Natural-gas fired heating appliance with draft hood: 360: 182: Liquefied-petroleum gas-fired heating appliance with draft hood: 360: 182: Gas-fired heating appliance, no draft hood: 460: 238: Glass melting furnaceGet Price
Selective non-catalytic reduction involves the injection of a NOx reducing agent, such as ammonia or urea, into the boiler exhaust gases at a temperature of approximately 1400-1600°F. The ammonia or urea breaks down the NOx in the exhaust gases into water and atmospheric nitrogen. Selective non-catalytic reduction reduces NOx up to 70%.Get Price
However, a very high ER can lower the adiabatic flame temperature and reduce the efficiency of the heat exchanger from the boiler or the furnace in which combustion occurs. It was noted that the ER from the primary air inlet alone varied between 1.45 and 2.46, with an average of 2.06, indicating that the secondary air inlet may not be required.Get Price
Heating boiler gauges: this article describes the combination pressure & temperature gauge found on most hydronic (hot water) heating systems. The boiler gauge gives helpful temperature or pressure readings that tell us if the boiler is operating normally. The same pressure and temperature readings at a boiler can help diagnose problems such as TP valve leaks, cold …Get Price
Some fan-assisted, non-condensing furnaces and boilers, installed between 1987 and 1993, may be vented horizontally through high-temperature plastic vent pipe (not PVC pipe, which is safely used in condensing furnaces).Get Price
Boiler Gauges, how to read the temperature & pressure Get Price
Selective non-catalytic reduction involves the injection of a NOx reducing agent, such as ammonia or urea, into the boiler exhaust gases at a temperature of approximately 1400-1600°F. The ammonia or urea breaks down the NOx in the exhaust gases into water and atmospheric nitrogen. Selective non-catalytic reduction reduces NOx up to 70%.Get Price
Boilers are typically between 75% and 96% efficient in the primary process of heating the water, but any un-insulated heating water piping will lower the overall efficiency of space heating. In addition to the boiler unit, a gas-fired boiler requires a feed water supply, a boiler loop/heat delivery system (e.g., hydronic radiators or fan coil Get Price
can be based on boiler outlet water temperature, boiler return water temperature or system supply temperature, depending on the parameter setting. Sequence of operation Table 1-1 shows control module normal sequences of operation for space heating and DHW operation. The combined operation sequence is for a typical application,Get Price
bustion in boiler furnace: 1.Air supply- Need adequate air for complete combustion. The rating (capacity) of a boiler can be 3.Temperature- all combustion reactions proceed and fly ash are carried up with the exhaust. Particles trapped up in boiler, economizer, airGet Price
Jul 14, 2017 · If it's an oil fired boiler the 130F lo-temp setting is too low, but if it's gas it's fine (just don't take it any lower.) With an oil boiler firing at 130F there will be corrosive condensation in the flue, and corrosive exhaust condensation on the boiler's heat exchanger plates, taking a toll on chimney & boiler lifespan.Get Price
Dec 17, 2019 · Generally, the lost heat is 6% of the heat input into the boiler furnace. The heat loss of exhaust gas increases by 0.5% when the temperature of exhaust gas increases by 12-15%. Therefore, exhaust gas temperature is one of the most important indicators of boiler operation. The following are the possible reasons for the increase in exhaust gas temperature in the …Get Price
Heating boiler gauges: this article describes the combination pressure & temperature gauge found on most hydronic (hot water) heating systems. The boiler gauge gives helpful temperature or pressure readings that tell us if the boiler is operating normally. The same pressure and temperature readings at a boiler can help diagnose problems such as TP valve leaks, cold …Get Price